ANALISIS REJECT RATE DI INSTALASI RADIOLOGI RUMAH SAKIT DR. GUNAWAN MANGUNKUSUMO AMBARAWA
DOI:
https://doi.org/10.58738/jhn.v4i1.1907Keywords:
Reject rate, Computed Radiography, Quality Assurance, Radiologi, Image Reject AnalysisAbstract
Radiology services require quality control to ensure the quality of diagnostic images. One of the indicators used is the reject rate. However, analyses of reject rates in Computed Radiography (CR) systems based on actual data and causative factors at healthcare facilities remain under-reported; consequently, information regarding patterns of reject incidents—which serves as a basis for service quality improvement—is limited. This gap indicates that radiographic quality control, particularly regarding Computed Radiography (CR) systems, requires contextual evaluation across various facilities. This study aims to analyze reject rates, causative factors, and efforts to reduce reject incidents at the Radiology Unit of RSGM Ambarawa. This is a descriptive study employing a quantitative approach supplemented by qualitative data. Primary data consisted of secondary data obtained from radiography reject logs, monthly film usage reports, and a summary of reject incidents at the RSGM Ambarawa Radiology Unit for the period of January–March 2026. Observations and interviews with three informants (the unit head and two radiographers) were conducted to enrich and verify the context, causative factors, and reject control measures. Analysis was performed by calculating reject rates using standard formulas and categorizing the causes of rejection. The results showed reject rates of 0.71% in January 2026 (18 CR rejects out of 2,530 films), 0.73% in February 2026 (17 CR rejects out of 2,338 films), and 1.01% in March 2026 (19 CR rejects out of 1,890 films). All values fell below the threshold of ≤2%. Factors contributing to image rejects included underexposure (20.75%), processing issues (20.75%), positioning errors (18.52%), motion artifacts (14.81%), overexposure (12.96%), and equipment-related issues (12.96%). Measures already implemented include briefings on exposure factor selection, improved patient communication, routine equipment maintenance, dual identity verification in accordance with Standard Operating Procedures (SOPs), and supervision of student interns. Future recommendations include developing an SOP for window settings, procuring Uninterruptible Power Supply (UPS) units, and integrating the PACS system.
References
Afsari, D., Utami, M. P., & Zanariah, Z. (2025). Gambaran pemakaian film pada computed radiography sebagai upaya efisiensi dan meningkatkan layanan kesehatan. JOURNAL of Public Health Concerns, 5(10), 693–698. https://doi.org/10.56922/phc.v5i10.1891
Artitin, C.-. (2022). Analisa Pengulangan (Repeat) Radiograf Di Unit Radiologi Rumah Sakit Umum Daerah Mohammad Natsir Solok. Jurnal Teras Kesehatan, 5(1), 25–30. https://doi.org/10.38215/jtkes.v5i1.72
Atkinson, S., Neep, M., & Starkey, D. (2020). Reject rate analysis in digital radiography: an Australian emergency imaging department case study. Journal of Medical Radiation Sciences, 67(1), 72–79. https://doi.org/10.1002/jmrs.343
Barau, N. I., Mangset, W. E., Ijeoma, I.-O. M., & Mohammed, Y. B. (2025). Evaluation of Quality Control Standards in Medical Diagnostic X-Ray Facilities in North-Eastern Nigeria. Nigerian Journal of Physics, 34(1), 110–117. https://doi.org/10.62292/njp.v34i1.2025.334
Bisra, M., Fadila, R., & Purnamasari, D. (2025). Analisis Faktor Penyebab Repeat Exposure Pada Citra Radiograf Di Instalasi Radiologi Rumah Sakit Pekanbaru Medical Center (PMC). Innovative: Journal Of Social Science Research, 5(4), 9101–9112. https://doi.org/10.31004/innovative.v5i4.21063
Calatayud-Jordán, J., Campayo-Esteban, J. M., Gras-Miralles, P., & Villaescusa-Blanca, J. I. (2024). Image reject analysis and rejection causes in digital radiography at a university hospital through estimates of patient doses. Radiation Protection Dosimetry, 200(3), 274–284. https://doi.org/10.1093/rpd/ncad301
Claudia, S., Agustina, A., Abdi, M. M., Hasani, A. R., Mulia, U. S., & Persalinan, P. (2024). Jurnal Dinamika Kesehatan Terpadu Fasilitas Kesehatan Jurnal Dinamika Kesehatan Terpadu. Jurnal Dinamika Kesehatan Terpadu, 5(4), 158–168.
Delis, H., Christaki, K., Healy, B., Loreti, G., Poli, G. L., Toroi, P., & Meghzifene, A. (2017). Moving beyond quality control in diagnostic radiology and the role of the clinically qualified medical physicist. Physica Medica, 41, 104–108. https://doi.org/10.1016/j.ejmp.2017.04.007
Dudhe, S. S., Mishra, G., Parihar, P., Nimodia, D., & Kumari, A. (2024). Radiation Dose Optimization in Radiology: A Comprehensive Review of Safeguarding Patients and Preserving Image Fidelity. Cureus. https://doi.org/10.7759/cureus.60846
Ofori-Manteaw, B., & Amevorwoshie, P. E. (2025). Image Reject Patterns in Computed Radiography: Insights From a Ghanaian Radiology Department. Journal of Medical Radiation Sciences, 87–95. https://doi.org/10.1002/jmrs.70039
Rastegar, S., Beigi, J., Saeidi, E., Dezhkam, A., Mobaderi, T., Ghaffari, H., Mehdipour, A., & Abdollahi, H. (2019). Reject analysis in digital radiography: A local study on radiographers and students’ attitude in Iran. Medical Journal of The Islamic Republic of Iran. https://doi.org/10.47176/mjiri.33.49
Rochmayanti, D., Adi, K., & Widodo, C. E. (2023). Repeat Analysis Program As A Quality Assurance System For Radiology Management: Causal Repeat And An Overview. Journal of Medical Imaging and Radiation Sciences, 54(3), S31. https://doi.org/10.1016/j.jmir.2023.06.112
Stephenson‐Smith, B., Neep, M. J., & Rowntree, P. (2021). Digital radiography reject analysis of examinations with multiple rejects: an Australian emergency imaging department clinical audit. Journal of Medical Radiation Sciences, 68(3), 245–252. https://doi.org/10.1002/jmrs.468
Suraningsih, N., Rosidah, S., & Felayani, F. (2015). Analisa Penolakan Radiograf di Instalasi Radiologi Rumah Sakit Bhayangkara Semarang. Jurnal Ilmu Dan Teknologi Kesehatan STIKes Widya Husada Semarang, 6(1), 7–14.