STUDI KASUS PROTEKSI RADIASI PADA KONDISI KEGAWATDARURATAN PEMERIKSAAN PEDIATRIK PADA KASUS SUSP. EVENTRASIO DIAFRAGMA
DOI:
https://doi.org/10.58738/jhn.v4i1.1835Keywords:
Radiation protection, Pediatric, Entrance Surface Dose, OMDAbstract
Radiation protection aims to safeguard patients by applying the principles of justification, optimization, and limitation, ensuring radiation doses remain as low as possible without compromising image quality. Pediatric patients exhibit high radiosensitivity because their body cells are actively developing, making them more susceptible to the biological effects of radiation. Pediatric emergencies often require rapid radiological examinations, such as in cases of suspected diaphragmatic eventration. Suboptimal use of exposure factors (kVp, mAs) and collimation settings can increase radiation doses received by pediatric patients. This study aims to describe the Entrance Surface Dose (ESD) values, analyze the influence of technical factors on ESD, and evaluate compliance with IAEA Diagnostic Reference Level (DRL) standards. A mixed-methods approach combining qualitative and quantitative methods was employed. The study subject was a 3-day-old pediatric patient undergoing an OMD (esophagogastroduodenal) examination during an emergency at the Radiology Department of Sleman Regional General Hospital (RSUD Sleman). Data were collected between September 2025 and June 2026 through observation and interviews with four informants: one radiologist, two radiographers, and one medical physicist; quantitative data were derived from Dose Area Product (DAP) values. The OMD examination involved five exposures—AP (first), AP (second), LPO, LPO (repeat), and RPO—resulting in a total ESD of 0.389 mGy. The total DAP was 508.7 mGy·cm², which remains below the IAEA DRL reference value of 760 mGy·cm² for the 0-year age group. Factors such as kVp, mAs, SID, and collimation area were found to directly influence ESD values. The use of a 42 × 42 cm collimation field was excessively large and suboptimal for a pediatric patient.
References
Ahmad Zaky Faudi, Fisnandya Meita Astari, A. P. U. (2023). Studi kasus prosedur pemeriksaan oesophagus maag duodenum pada kasus atresia duodenum di RSUD Dr. Soedono Madiun.
Asriningrum Surdiyah. (2020). Efek Perubahan Dosis Radiasi Dan Kualitas Gambar Pada Hasil Radiograph Dengan Luas Kolimasi Berbeda. 6, 103–105.
Collins, S. P., Storrow, A., Liu, D., Jenkins, C. A., Miller, K. F., Kampe, C., & Butler, J. (2021). Merril’s Atlas Of Radiografic Positioning & Procedures.
Dudhe, S. S., Mishra, G., Parihar, P., Nimodia, D., & Kumari, A. (2024). Radiation Dose Optimization in Radiology: A Comprehensive Review of Safeguarding Patients and Preserving Image Fidelity. Cureus, 16(5), e60846. https://doi.org/10.7759/cureus.60846
Hiswara, E. (2023). Buku Pintar Proteksi dan Keselamatan Radiasi di Rumah Sakit.pdf.
Implications-an, R., & Review, U. (2025). Saudi Journal of Medicine and Public Health. 2(2).
Katsina, F. T. H., Abdullahi, M., Muhammed, G. B., & Usman, R. A. (2023). A periodical of the Faculty of Natural and Applied Sciences , UMYU , Katsina Determination of Entrance Surface Dose for Patients Undergoing Conventional Chest X-ray Examination at Radiology Department , Federal Teaching Hospital. 1(2), 68–76.
Kurnia Prayoga, A., & Meita Astari, F. (2026). Optimization Of Entrance Surface Dose (Esd) Through Variation of Focus To Film Distance (FFD) With Phantom on Emergency Thorax Radiography Using Mobile X-Ray Planes. 5(12), 13069–13080.
Lampignano, J. P., & Kendrick, L. E. (2018). Bontrager’s Textbook of Radiographic Positioning and Related Anatomy. Elsevier.
Lin, J., Chen, T., Liang, Y., Li, J., & Chou, M. (2025). An artificial intelligence model for predicting an appropriate mAs with target exposure indicator for chest digital radiography. 1–10.
Maulidya, I., Ade, I., & Liscyaningsih, N. (2025). Evaluation of diagnostic reference levels ( DRL ) in pediatric appendicogram examination for radiation safety improvement. 03006, 1–11.
Online, F. A., Davoodi, R., Eydian, M. R., Maraei, A., Branch, D., & Hospital, G. (2021). Journal of Radiation and Nuclear Medicine. 1, 23–28. https://doi.org/10.14302/issn.2766
Prastanti, A. D., Abimanyu, B., & Andrey, N. (2020). Optimasi Citra CR dan Limitasi Dosis dengan Pengaturan Kolimasi pada Radiograf Servikal. Jurnal Imejing Diagnostik (JImeD).
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2026 Author

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.